What's New in Vicon Nexus 2.1
        
 
 

New gap-filling options

The following gap-filling options are new in Nexus 2:

     Rigid Body Fill

     Kinematic Fill

The new gap-filling options are accessed in the usual way (in the Label/Edit tools pane in the Gap Filling section):

GapFillOpts_sm.png 

Rigid Body Fill

This option is the Nexus equivalent of the Replace 4 option, which is available in BodyBuilder.

Use it when a rigid or semi-rigid relationship exists between markers.

For example:

     Pelvis (LASI, RASI, LPSI, RPSI)

     Head (LFHD, RFHD, LBHD, RBHD)

Kinematic Fill

This option uses information about the connection of markers to segments in the labeling skeleton template (VST).